Pengaruh Diameter dan Kecepatan Kipas Kondensor terhadap Suhu AC Mobil

Authors

  • Muh. Agung Pribadi SMK Negeri Klakah Lumajang
  • Endry Maydiant SMK Negeri Klakah Lumajang
  • Sukardi Sukardi PDD Politeknik Negeri Malang

DOI:

https://doi.org/10.21776/ub.jrm.2019.010.02.11

Keywords:

Cooling System, Refrigeration, Freon R-134a

Abstract

The efficiency of the Air Conditioning (AC) system in a car depends on the process of compression, condensation, and evaporation. The new thought that arises is what if the diameter of the condenser fan blade is varied? The objectives of this study are: (1) to test the effect of the diameter of the condenser fan blade on AC temperature, and (2) to test the effect of condenser fan rotation speed on AC temperature. This research is using an experimental method. The results showed: 1) there was an effect of the diameter of the condenser fan on AC temperature, which was 16.7%; and 2) there is an influence of condenser fan rotation speed on AC temperature that is equal to 20.5%. These findings become a reference that to improve the performance of the AC, it can be done by increasing the heat transfer process in the condenser.

References

AZIZ, CANDRA YUSFI AMRI dan FIRDAUS, RAHMAT. 2018. Pemanfaatan Panas di Pipa Tekanan Tinggi Pada Mesin Pendingin (AC). Jurnal Rekayasa Mesin Vol.9, No.1, 15-21

DATTA, SANTANU PRASAD; DAS, PRASANTA KUMAR dan MUKHOPADHYAY, SIDDHARTHA. 2014. Effect of Refrigerant Charge, Compressor Speed and Air Flow through the Evaporator on the Performance of an Automotive Air Conditioning System. International Refrigeration and Air Conditioning Conference. Paper 1470

EFFENDY, MARWAN. 2005. Pengaruh Kecepatan Udara Pendingin Kondensor Terhadap Koefisien Prestasi Air Conditioning. Jurnal Teknik Gelagar, Vol. 16, No. 01, 51 - 58

SIAGIAN, SAUT. 2015. Analisis Karakteristik Unjuk Kerja Kondensor Pada Sistem Pendingin (Air Conditioning) Yang Menggunakan Freon R-134a Berdasarkan Pada Variasi Putaran Kipas Pendingin. Bina Teknika, Vol. 11 No. 2, 124-130

POERNOMO, HEROE. 2015. Analisis Karakteristik Unjuk Kerja Sistem Pendingin (Air Conditioning) Yang Menggunakan Freon R-22 Berdasarkan Pada Variasi Putaran Kipas Pendingin Kondensor. KAPAL, Vol. 12, No. 1

RIDHUAN, KEMAS dan ANGGA, I GEDE. 2014. Pengaruh Media Pendingin Air Pada Kondensor Terhadap Kemampuan Kerja Mesin Pendingin. TURBO, Vol. 3, N0. 2

SRIVIDHYA, V dan VENKATESWARA RAO, G. 2013. Improving the Heat Transfer Rate for Ac Condenser by Material and Parametric Design Optimization. International Journal of Engineering Research & Technology (IJERT), Vol. 2 Issue 1, 2278-0181

TJAHJONO, TRI dan ARNA, DESI. 2014. Optimasi Kecepatan Udara Pada Kondensor Terhadap Prestasi Kerja AC Mobil Dengan Fluida Kerja Freon 12. Media Mesin, Vol. 15, No. 2, 55-67

WANG, SHU JUN dan GU, JUN JIE. 2004. Experimental Analysis of an Automotive Air Conditioning System with Two-Phase Flow Measurements. International Refrigeration and Air Conditioning Conference. Paper 735.

WIDODO, EKO; SETIAWAN, DIGDO LISTYADI dan KRISTIANTA, FX. 2014. Pengaruh Penambahan Fan Pembuang Udara pada Kondensor terhadap Prestasi Kerja Mesin Pendinging menggunakan Refrigeran LPG. Artikel Ilmiah Hasil Penelitian Mahasiswa Universitas Jember

Downloads

Published

2019-08-31

Issue

Section

Articles