Pengaruh Penggunaan Fan dan Debit Fluida terhadap Efisiensi Kerja Atmospheric Water Generator

Authors

  • Bagus Prabowo Vidiyanto Universitas Negeri Semarang (Semarang State University)
  • Widya Aryadi Universitas Negeri Semarang (Semarang State University)
  • Ahmad Mustamil Khoiron Universitas Negeri Semarang (Semarang State University)
  • Samsudin Anis Universitas Negeri Semarang (Semarang State University)

DOI:

https://doi.org/10.21776/ub.jrm.2019.010.02.1

Keywords:

Atmospheric Water Generator, Discharge, Fan, COP, Efficiency

Abstract

The purposes of this study are to investigate the effect of condenser cooling fan addition and airflow rate on the performance of Atmospheric Water Generator (AWG). In this work, humid air from the environment was supplied into AWG at 15 lpm. Then, it was condensed in the system with and without using a condenser cooling fan. The fan airflow rate also varied from 0.09 m3/s to 0.16 m3/s in order to better assess AWG performance. The results showed that the use of a condenser cooling fan can improve the Coefficient of Performance (COP) and the efficiency of the Atmospheric Water Generator. The average value of COPactual of 2.499 and the highest efficiency of 79.07% was achieved by an Atmosphere Water Generator equipped with a condenser cooling fan at an airflow rate of 0.16 m3/s.

References

TRIPATHI, A., S. TUSHAR, S. PAL, S. LODH, S. TIWARI, dan R. S. DESAI, 2016, Atmospheric Water Generator. International Journal of Enhanced Research in Science, Technology & Engineering 5(4): 69-72.

BULA, M., S. WAHYUDI, dan N. HAMIDI, 2010, Pengaruh Diameter Inner-Helical Fin Terhadap Characteristic of Performance Counter Flow Heat Exchanger, Jurnal Rekayasa Mesin 1(3): 100-106.

POERNOMO, H, 2015, Analisis Karakteristik Unjuk Kerja Sistem Pendingin (Air Conditioning) yang Menggunakan Freon R-22 Berdasarkan pada Variasi Putaran Kipas Pendingin Kondensor, Jurnal KAPAL 12(1): 1-8.

USMAN, S., S. WAHYUDI, dan B. D. ARGO, 2010, Pengaruh Ketebalan Inner-Helical Fin terhadap Characteristic of Performance pada Head Exchanger, Jurnal Rekayasa Mesin 1(3): 108-114.

WIDODO, E., D. L. SETIAWAN., F. X. KRISTIANTA, 2014, Pengaruh Penambahan Fan Pembuang Udara pada Kondensor terhadap Prestasi Kerja Mesin Pendingin Menggunakan Refrigeran LPG, http://repository.unej.ac.id/bitstream/handle/123456789/72549/Eko%20Widodo.pdf?sequence=1. Diakses: 14 Maret 2018 (15:00).

RIDHUAN, K. dan I. G. ANGGA J, 2014, Pengaruh Media Pendingin Air pada Kondensor Terhadap Kemampuan Kerja Mesin Pendingin. Jurnal TURBO 3(2): 1-6.

SANTOSO, M. D, 2017, Pengaruh Jumlah Kipas Kondensor Terhadap Karakteristik Showcase Dengan Daya Kompresor 1/3 HP, Skripsi, Program Sarjana Universitas Sanata Dharma Yogyakarta, Yogyakarta.

SIAGIAN, S, 2015, Analisis Karakteristik Unjuk Kerja Kondensor Pada Sistem Pendingin (Air Conditioning) Yang Menggunakan Freon R-134 A Berdasarkan Pada Variasi Putaran Kipas Pendingin, Jurnal BINA TEKNIKA 11(2): 124-130.

INVENTEC, 2009, R600A, http://www.inventec.dehon.com/documents/pdf/8d8f18d926a2e9014535f0 df682c7283.pdf. Diakses: 6 September 2018 (10:45).

SUGIYONO, 2015, Metode Penelitian Pendidikan (Pendekatan Kuantitatif, Kualitatif dan R&D), Cetakan Ke 21, Bandung: Alfabeta.

ALHAKIM, R, 2018, Produksi dan Uji Karakteristik Bio-Oil dari Bahan Baku Minyak Goreng Menggunakan Proses Pirolisis Berbasis Iradiasi Gelombang Mikro, Skripsi, Program Sarjana Universitas Negeri Semarang, Semarang.

BUDIANDONO, G. N, 2017, Pengaruh Suhu dan Persentase Campuran Biodiesel Dengan Dexlite terhadap Pola Pengabutan dan Kinerja Fuel Injection Pump Diesel 1 Silinder, Skripsi, Program Sarjana Universitas Negeri Semarang, Semarang.

PERDANA, G.R., N. ILMINNAFIK, dan D. LISTYADI, 2014, Pengaruh Penggunaan Water Cooled Condenser Terhadap Prestasi Kerja Mesin Pendingin Menggunakan Refrigeran LPG, http://repository.unej.ac.id/bitstream/handle/123456789/69307/Galla%20Rezki.pdf?sequence=1. Diakses: 2 April 2018 (09:48).

HAJIDAVALLO, E., dan H. EGHTEDARI, 2010, Performance Improvement of Air-Cooled Refrigeration System by using Evaporatively Cooled Air Condenser, International Journal of Refrigeration 33(5): 982-988.

KUSBANDONO, W., dan P. K. PURWADI, 2016, Pengaruh Adanya Kipas yang Mengalirkan Udara Melintasi Kondensor Terhadap COP Dan Efisiensi Mesin Pendingin Showcase, Prosiding Simposium Nasional XI Rekayasa Teknologi Industri dan Informasi, Sekolah Tinggi Teknologi Nasional Yogyakarta, Yogyakarta, 313-317.

Downloads

Published

2019-08-31

Issue

Section

Articles